Mocomtech CDM-570 User Manual

Page 436

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 4

Appendix F

MN/CDM570L.IOM

F.3.3.30 (ODU,ENABLE,1:1,CSAT#1,CONFIG, MISCELLANEOUS,LNA)
FAULT-LOGIC
(ODU,ENABLE,1:1,CSAT#2,CONFIG,

MISCELLANEOUS,LNA)

FAULT-LOGIC
(ODU,ENABLE,STAND-ALONE,CONFIG,MISCELLANEOUS,LNA)
FAULT-LOGIC

LNA Fault Logic: Summary
No-Summary (

◄ ►,

ENT)


The user is prompted to select either Summary or No Summary, using the ◄ ► arrow
keys, then to press ENT. This controls whether or not a LNA Current-Window fault will
activate the SUMMARY FAULT RELAY. This allows the user to select whether or not
to switch the ONLINE/OFFLINE CSAT in the event of a LNA current-window fault.

F.3.3.31 (ODU,ENABLE,1:1,CSAT#1,CONFIG,MISCELLANEOUS)

EXT-REF

(ODU,ENABLE,1:1,CSAT#2,CONFIG,MISCELLANEOUS)

EXT-REF

(ODU,ENABLE,STAND-ALONE,CONFIG,MISCELLANEOUS)

EXT-REF

ExternalRef Fault Logic:
Summary No-Summary (

◄ ►

)

The user is prompted to select either Summary or No-Summary, using the ◄ ► arrow
keys, then to press ENT. NOTE: The CSAT will automatically lock to an external 5 or
10 MHz reference independent of the state of this selection. This selection determines
whether or not the Summary Fault Relay is activated if the CSAT loses lock with the
external reference.

F.3.3.32 (ODU,ENABLE,1:1,CSAT#1,CONFIG,MISCELLANEOUS)

REF-ADJUST

(ODU,ENABLE,1:1,CSAT#2,CONFIG,MISCELLANEOUS)

REF-ADJUST

(ODU,ENABLE,STAND-ALONE,CONFIG,MISCELLANEOUS)

REF-ADJUST

Internal Ref Adjustment:
087 (
▲ ▼,ENT)

The user is prompted to edit the Internal 10MHz Reference setting using the ▲ ▼ arrow
keys, then to press ENT. The value will scroll between 000 and 255. NOTE: The
Internal Reference is adjusted in the factory to be very accurate with the default setting of
087. This parameter is made available to compensate for the long-term frequency drift of
the oscillator.