8 (config) rx (receive) – Mocomtech CDM-570 User Manual

Page 144

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 4

Front Panel Operation

MN/CDM570L.IOM

6–20

6.8

(CONFIG) RX (Receive)

The sub-branches available are:

Select FEC, Dem, Code, Data, Frq, Acq, Descram, Buf, Inv or EbNo using the ◄ ►
arrow keys, then press ENTER. The user will then be taken to a further sub-menu. Each of
these choices is described briefly in the table below:


FEC

(Forward Error Correction) This sub-menu permits the user to select the
method of FEC used for reception (Viterbi, TPC, etc.). FEC type takes
the highest configuration priority.

Dem

(Demodulation) This sub-menu permits the user to select the
modulation type used for reception (BPSK, QPSK, 8-PSK, etc.). The
choice of demodulation will depend on the FEC type chosen.

Code

(FEC Code Rate) This sub-menu permits the user to select the FEC
Code Rate used for reception (Rate 1/2, Rate 3/4, etc.). The choice of
Code Rate will depend on both the FEC type and Demodulation
selected.

Data

(Data Rate) This sub-menu permits the user to select the receive data
rate, in steps of 1 bps. The choice of data rate will depend on the FEC
type, Demodulation, and Code Rate selected.

Frq

(Frequency) This sub-menu permits the user to select the transmit
frequency, in steps of 100Hz.
CDM-570L range: 950 MHz to 1950 MHz
CDM-570 range: 50 to 90 MHz and 100 to 180 MHz

Acq

(Acquisition) This sub-menu permits the user to determine the amount
of frequency uncertainty the demodulator will search over in order to
find and lock to an incoming carrier.

Descram

(Descrambler) This sub-menu permits the user to select whether or not
data descrambling is used.

Buf

(Buffer) This sub-menu permits the user to select whether or not the
Plesiochronous/Doppler buffer is used, and if so, the size of that buffer.

Inv

(Inversion) This sub-menu permits the user to invert the sense of the
received spectrum, or to invert the sense of the received baseband data.

EbNo

(Eb/No Alarm threshold) This sub-menu permits the user to determine
the Eb/No alarm threshold.








Rx:FEC Dem Code Data Frq
Acq Descram Buf Inv EbNo

Advertising
This manual is related to the following products: