4 administration > power management – Minicom Advanced Systems SMART 232 User Manual

Page 19

Advertising
background image

USER GUIDE

18

11.4 Administration > Power Management

Where you have a Minicom Serial Remote Power Switch (SRPS), connect it to the
RPS port of the Smart 216.

Configure the Power Management switch as follows:

1. From the menu, click Power Management. The Power Management window

appears, see Figure 16.

Figure 17 Power Management

2. Select the number of sockets on the power management switch in the Number

of Sockets drop-down menu (SRPS has 8)

3. Click

. The appropriate number of Managed by Sockets and

Server Name drop-down menus appear.

4. Select the PDU type (default is SRPS).

5. Match the sockets to the servers. For each socket select the server name

connected to it from the drop-down menu.

When there is a double or triple power supply, you need to assign multiple sockets
to the same KVM port.