2 troubleshooting table for synthesizer – Motorola CP150TM User Manual

Page 169

Advertising
background image

6880309N62-C

June, 2005

UHF Troubleshooting Tables: Troubleshooting Table for Synthesizer

11-3

11.2

Troubleshooting Table for Synthesizer

Table 11-2. Troubleshooting Table for Synthesizer

Symptom

Possible Causes

Procedure

Corrective Action

Synthesizer Out of
Lock (RX mode
only)

1. VCO fault

Verify oscillator is working, check RF
level at U251-10 per schematic.

Check dc voltages at U251 pin 2
through 6 and 10 per

Table 11-4

.

Verify steering line voltage is
between ~3V and 10V.

Check VCO tank components
connected to U251-5 and 6.

Check for shorts/opens, replace
U251.

Check D251 and associated
components.

2. Synthesizer fault

Verify TRB line (from U201-2 to
U251-19) is low in RX mode

Check for shorts, check U201
voltages per

Table 11-4

,

replace U201 if incorrect.

3. Programming fault

Verify RX channel programming is
correct.

Re-program if necessary.

Synthesizer Out of
Lock (TX mode
only)

1. VCO fault

Verify oscillator is working, check RF
level at U251-10 per schematic.

Check dc voltages at U251 pins
1,3,4,10,15,16 per

Table 11-4

.

Verify steering line voltage is
between ~3V and 10V.

Check VCO tank components
connected to U251-15 and 16.

Check for shorts/opens, replace
U251.

Check D261 and associated
components.

2. Synthesizer fault

Verify TRB line (U201-2 to U251-19)
is high (3V) in TX mode

Check for shorts, check U201
voltages per

Table 11-4

,

replace U201 if incorrect.

3. Programming fault

Verify TX channel programming is
correct.

Re-program if necessary.

Synthesizer Out of
Lock (RX and TX
modes)

1. VCO fault

Check that RF level at U251-12 is at
least 150 mV (VHF) or -12 to -20
dBm (UHF)

If low/missing, check L276,
C276-7, R276.

2. Synthesizer fault

Check that RF level at U201-32 is at
least 150 mV (VHF) or -12 to -20
dBm (UHF).

Verify steering line voltage is
between ~3V and 10V.

If correct, check/replace U201.
If incorrect, check R248 and
C241.

Check loop filter components
R243-5 and C243-5.

3. DC voltage fault

Verify 4.5V dc at U201-28.

Verify 12.1V dc at U201-47

Check C231-233, etc., for
shorts. If OK check/replace
U201.

Check for 3V 1.05 MHz sq
waves at U201-14 and 15.
Check C218-228, D220-221.

4. Programming fault

Verify channel programming is cor-
rect.

Re-program if necessary.