10 acoustics, 11 electromagnetic immunity, Acoustics – Maxtor STM3160215AS User Manual

Page 31: Electromagnetic immunity

Advertising
background image

DiamondMax 21 Serial ATA Product Manual, Rev. C

25

2.10

Acoustics

Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea-
surements are consistent with ISO document 7779. Sound power measurements are taken under essentially
free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.

Note. For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined

by the following equation:

(Number of seeks per second = 0.4 / (average latency + average access time)

*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and

power to operational levels.

**Measured in performance mode.

***Measured in quiet mode.

2.11

Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:

Table 8:

Fluid Dynamic Bearing (FDB) motor acoustics

Idle*

Seek

STM3500630AS

2.8 bels (typ)

3.0 bels (max)

3.7 bels (typ)**

3.9 bels (max)**

STM3320620AS, STM3320820AS, and STM3250820AS

2.5 bels (typ)

2.9 bels (max)

3.0 bels (typ)**

3.2 bels (max)**

STM3250824AS

2.7 bels (typ)

2.9 bels (max)

3.4 bels (typ)**

3.6 bels (max)**

STM3250310AS

2.6 bels (typ)

2.7 bels (max)

2.7 bels (typ)***

2.8 bels (max)***

STM3160815AS, STM3160215AS, STM380815AS

STM380215AS and STM340215AS

2.8 bels (typ)

3.0 bels (max)

3.0 bels (typ)***

3.2 bels (max)***

Table 9:

Radio frequency environments

Test

Description

Performance level

Reference standard

Electrostatic
discharge

Contact, HCP, VCP: ± 4

kV; Air:

± 8 kV

B

EN 61000-4-2: 95

Radiated RF
immunity

80 to 1,000 MHz, 3 V/m,

80% AM with 1 kHz sine

900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz

A

EN 61000-4-3: 96

ENV 50204: 95

Electrical fast
transient

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN 61000-4-4: 95

Surge immunity

± 1 kV differential, ± 2 kV common, AC mains

B

EN 61000-4-5: 95

Conducted RF
immunity

150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine A

EN 61000-4-6: 97

Voltage dips,
interrupts

0% open, 5 seconds

0% short, 5 seconds

40%, 0.10 seconds

70%, 0.01 seconds

C

C

C

B

EN 61000-4-11: 94

Advertising