Configuring the internal ethernet port, Configuring management ports on i/o modules, Saving and restoring the configuration file – IBM BladeCenter T Type 8720 User Manual

Page 39: Configuring an i/o module, What to configure, Saving, Restoring, Configuration, File, Configuring

Advertising
background image

module

automatically

when

needed).

Otherwise,

configure

the

DHCP

setting

as

you

prefer.

You

must

configure

the

static

IP

address

only

if

DHCP

is

disabled.

IP

address

-

The

IP

address

for

the

management

module.

The

IP

address

must

contain

four

integers

from

0

through

255,

separated

by

periods,

with

no

spaces

or

consecutive

periods.

The

default

setting

is

192.168.70.125.

Subnet

mask

-

The

subnet

mask

must

contain

four

integers

from

0

to

255,

separated

by

periods,

with

no

spaces.

The

default

setting

is

255.255.255.0

Gateway

address

-

The

IP

address

for

your

network

gateway

router.

The

gateway

address

must

contain

four

integers

from

0

through

255,

separated

by

periods,

with

no

spaces.

Configuring

the

internal

Ethernet

port

Under

MM

Control,

click

Network

Interfaces

Internal

Network

Interface

(eth1).

This

interface

communicates

with

the

network-interface

I/O

modules,

such

as

the

Ethernet

switch

module

or

the

Fibre

Channel

switch

module.

v

Specify

the

IP

address

to

use

for

this

interface.

The

IP

addresses

for

the

internal

Ethernet

port

(eth1)

and

external

Ethernet

port

(eth0)

must

be

on

the

same

subnet.

v

(Optional)

Configure

the

locally-administered

MAC

address

for

this

interface;

the

other

fields

(data

rate,

duplex

mode,

maximum

transmission

unit

(MTU),

and

burned-in

MAC

address)

are

read-only.

Configuring

management

ports

on

I/O

modules

Under

I/O

Module

Tasks,

click

Management;

then,

click

the

bay

number

that

corresponds

to

the

I/O

module

that

you

are

configuring.

v

In

the

New

Static

IP

address

fields,

specify

the

IP

address

to

use

for

this

interface.

The

new

static

IP

address

must

be

on

the

same

subnet

as

the

internal

network

interface

(eth1).

v

Click

Advanced

Management

Advanced

setup.

Enable

the

external

ports.

v

Click

Advanced

Management

Advanced

setup.

(Optional)

Enable

external

management.

Saving

and

restoring

the

configuration

file

After

you

have

configured

the

management

module,

you

can

save

the

configuration

file

to

a

drive

attached

to

the

system

running

the

management-module

Web

interface.

Then,

if

the

configuration

in

the

management

module

becomes

damaged

or

if

the

management

module

is

replaced,

you

can

restore

the

saved

configuration

file

to

the

management

module.

Use

the

management-module

Web

interface

to

save

and

restore

the

configuration

file

(MM

Control

Configuration

File).

Configuring

an

I/O

module

To

connect

any

of

the

blade

servers

to

the

network,

you

must

have

an

Ethernet

switch

module

installed

in

I/O-module

bay

1

or

2,

or

a

pass-thru

module

in

I/O-module

bay

1

or

2

connected

to

an

external

Ethernet

switch.

If

you

have

an

I/O

expansion

option

installed

on

one

or

more

blade

servers,

you

must

have

compatible

I/O

modules

(switch

modules

or

other

compatible

modules)

in

I/O

module

bays

3

or

4.

See

“Removing

and

installing

I/O

modules”

on

page

60

for

information

about

the

location

and

purpose

of

each

I/O

module.

What

to

configure

You

must

configure

switch-module

IP

addresses

and

subnet

masks

through

the

management-module

Web

interface

to

communicate

with

the

management

module

Chapter

2.

Configuring

the

BladeCenter

T

unit

29