Вк 10, Operation, Control and crossover – Interfire Audio G1-3000 User Manual

Page 10

Advertising
background image

LINE INPUT

CH1

CH2

GAIN

LPF

6V

0.2V

50Hz 250Hz 0dB 12dB

BASS BOOST

SLAVE

MASTER

MASTER
/SLAVE

REMOTE

GAIN CONTROL

8

1

2

3

4

5

6

7

1. RCA Input Jacks 2. Input Level Control 3. Low Pass Frequency
4. Bass Boost
5. Remote Control Jack 6. Master/Slave Switch 7. Slave Input Jack

OPERATION

Control and Crossover

1. RCA Input Jacks - Low level-high impedance inputs. Use high quality RCA cables designed

for mobile applications.

2. Input Level Control - Adjust the input level for the marked channels. Turn clockwise to

increase the level, counterclockwise to decrease. Amplifiers will run cooler and produce

less system noise at lower level settings.

3. Low Pass Frequency - Adjust the crossover frequency by turning clockwise to set to a higher

frequency, counterclockwise to set to a lower frequency.

4. Bass Boost - Adjust the sub boost level of the selected frequency output from 0dB to 12dB.

5. Remote Control Jack - For connecting the remote control module to the amplifier.

6. Master/Slave Switch - Select the remote level control or the on-board level control as the

master control.

7. Slave Input Jack - Used to connect to another amplifier when bridging 2 amps together.

The Slave mode bypasses normal input jacks and controls.

Advertising