Keyboard/trackpoint-related symptoms, Indicator-related symptoms, Power-related symptoms – IBM R31 User Manual

Page 51

Advertising
background image

Keyboard/TrackPoint-Related
Symptoms

Symptom/Error

FRU/Action in Sequence

Keyboard (one or more
keys) doesn’t work.

v Go to “FRU tests” on page 54.
v Reseat keyboard cable.
v Keyboard
v System board

TrackPoint does not
work.

v Go to “FRU tests” on page 54.
v Reseat keyboard cable.
v Keyboard
v System board

Indicator-Related Symptoms

Symptom/Error

FRU/Action in Sequence

Indicator incorrectly
remains off or on, but
system runs correctly.

v Reseat Inveter/LED board

(13.3

″/14.1″)

v Inveter/LED board (13.3″/14.1″)
v System board
v Coaxial cable

Power-Related Symptoms

Symptom/Error

FRU/Action in Sequence

Power shuts down during
operation.

v Go to “Power systems checkout” on

page 36.

v AC Adapter
v Battery assembly
v Keyboard
v System board

The system doesn’t
power on.

v Go to “Power systems checkout” on

page 36.

v AC Adapter
v Battery assembly
v Keyboard
v System board

The system doesn’t
power off.

v Go to “Power systems checkout” on

page 36.

v Hold and press the power switch

for more than 4 seconds.

v Keyboard
v System board

MT 2656, 2657, 2676

45

Advertising
This manual is related to the following products:

R30