Intelligent Motion Systems MDO17Plus User Manual

Mdrive17plus speed control, Quick reference

Advertising
background image

Mechanical Specifications

MDrive17Plus Speed Control Quick Reference R020708

Quick Reference

MDrive17Plus

Speed Control

Notes and Warnings

Installation, configuration and maintenance must be carried out by qualified

technicians only. You must have detailed information to be able to carry out this

work. This information can be found in the user manuals.
• Unexpected dangers may be encountered when working with this product!

• Incorrect use may destroy this product and connected components!
The user manuals are not included. You can obtain them from the Internet at:

http://www.imshome.com/mdrive17plus_mdo.html.

Required for Setup*

PC running Microsoft

®

Windows XP Service Pack 2 or greater.

IMS SPI Motor Interface (available online)

+12 to +48 VDC unregulated linear or switching power supply. (Recom-

mended: IMS IP404 or ISP200-4)
10 kΩ Potentiometer for velocity control (or appropriate current source if

using current mode)
Two (2) SPST switches or controller I/O points to control axis direction

and the on/off state of the internal clock generator.
SPI communications interface (Recommended: IMS MD-CC300-001 or

MD-CC302-001 Communication Converters)

Depending on your MDrivePlus connectors configuration, you may also need:

If using a 7-pin pluggable terminal IMS recommends 22 AWG shielded

twisted pairs for logic wiring. Wire guage for for power connection varies

with the distance from the MDrive and current. See MDrivePlus product

manual.

* If you purchased your MDrivePlus with a QuickStart Kit, you have received all

of the connecting cables needed for initial functional setup and system testing.

Getting Started

All documentation, software and resources are available online at:

http://www.imshome.com/mdrive17plus_mdo.html

Connecting Power and I/O

Your MDrivePlus is configured with power and I/O combined on a single con-

nector. Please refer to the opposite side of this document for connecting details

and available IMS connectivity options including Prototype Development Cables

and Mating Connector Kits.

Connecting Communications

Connect IMS USB to SPI communications converter to MDrivePlus and

1.

PC.
Install the communication converter drivers onto PC (available online).

2.

Install and open SPI Motor lnterface.

3.

Apply power to MDrivePlus.

4.

Parameters may be adjusted via two screens, the Motor Settings screen

5.

or the I/O settings screen (shown below), accesible via the View menu.

All documentation, software, program examples and resources are available

online at: http://www.imshome.com/mdrive17plus_mdo.html

MDrive17Plus Speed Control Specifications

Electrical Specifications

Input Voltage (+V) Range*

+12 to +48 VDC

Max Power Supply Current (Per MDrive17Plus)*

2 A

*Actual Power Supply Current will depend on Voltage and Load.

Environmental Specifications

Operating Temperature
(non-condensing)

Heat Sink

-40°C to +85°C

Motor

-40°C to +100°C

Input Specifications

Analog Input

A/D Resolution

10 Bit

Range (Voltage Mode)

0 to +5VDC, 0 to +10 VDC

Range (Current Mode)

0 to 20 mA, 4 to 20 mA

Range (PWM)

15 to 20 kHz

Stop/Start and Direction

Range

TTL

Logic Threshold (Logic 0)

< 0.8 VDC

Logic Threshold (Logic 1)

> 2.2 VDC

Internal Pull-Up Resistance

20 kΩ

Protection

Transient

Communications Specifications

Protocol

SPI

Motion Specifications

Velocity

Oscillator Frequency (Max.)

5 MHz

Resolution

0.5961 Steps/Second

Acceleration/Deceleration
Range

1.5 x 10

9

Steps/Second

2

Resolution

90.9 Steps/Second

2

Number of Microstep Resolution Settings

20

Available Microsteps Per Revolution

200

400

800

1000

1600

2000

3200

5000

6400

10000

12800

20000

25000

25600

40000

50000

51200

36000

1

21600

2

25400

3

1=0.01 deg/µstep 2=1 arc minute/µstep 3=0.001 mm/µstep

Setup Parameters

MDrivePlus Speed Control Setup Parameters

Name

Function

Range

Units

Default

A1

Analog Input Mode

0 to +5 VDC, 0 to +10 VDC,

4 to 20 mA, 0 to 20 mA, 15 to

25kHz PWM

0 to +5

VDC

ACCL

Acceleration

91 to 1.5 X 10

9

steps/sec

2

1,000,000

C

Joystick Center

0 to 1022

counts

0

DB

Deadband

0 to 255

counts

1

DECL

Deceleration

91 to 1.5 X 10

9

steps/sec

2

1,000,000

DIR

Motor Direction Override

Clockwise/Counterclockwise

CW

FAULT

Fault/Checksum Error

Error Code

None

FS

Full Scale

1 to 1023 (205 to 1023 – 4 to

20 mA mode)

counts

1023

HCDT

Hold Current Delay Time

HCDT + MSDT <= 65535

milliseconds

500

IF

Analog Input Filter

1 to 1000

counts

1

MHC

Motor Hold Current

0 to 100

percent

5

MRC

Motor Run Current

1 to 100

percent

25

MSDT

Motor Settling Delay Time

MSDT + HCDT <= 65535

milliseconds

0

MSEL

Microstep Resolution

1, 2, 4, 5, 8, 10, 16, 25,

32, 50, 64, 100,108, 125,

127,128, 180, 200, 250, 256

µsteps per

full step

256

SSD

Stop/Start Debounce

0 to 255

milliseconds

0

VI

Initial Velocity

0 to < VM

steps/sec

1000

VM

Maximum Velocity

VI to 5,000,000

steps/sec

768000

USER ID

User ID

Customizable

1-3

characters

IMS

Note: Parameter settings may be changed on-the-fly.

Dimensions in inches (mm)

Motor Length LMAX1 (Single Shaft

or Internal Encoder)

LMAX2 (Control Knob

or External Encoder)

Single

2.20 (55.9)

2.79 (70.9)

Double

2.43 (61.7)

3.02 (76.7)

Triple

2.77 (70.4)

3.37 (85.6)

P1

Connector

Option

2.30

(58.3)

P2

1.19

(30.2)

LMAX2

LMAX

0.177

(4.49 )

0.94

(23.9)

Connector

Option

Ш 0.866

(Ш 21.996)

Ш 0.1968

(Ш 4.999)

1.68 SQ.

(42.7 SQ.)

1.220 SQ.

(31.0 SQ.)

4X M3x0.5 THREAD

x0.15 MIN DEEP

Advertising