ntax:

Visual C++ 6.0 / Boland C++ Builder 6.0:

short IMC_StrobeControl_SetConfiguration (HANDLE Camera_Handle, unsigned short

sStrobeIndex, bool bOnOff, bool bPolarity, unsigned long lDelay, unsigned long

lDuration);

Visual Basic 6.0

IMC_StrobeControl_SetConfiguration (ByVal Camera_Handle As Long, ByVal

sStrobeIndex As Integer, ByVal bOnOff As Boolean, ByVal bPolarity As Boolean, ByVal

lDelay As Long, ByVal lDuration As Long) As Integer

C#.NET 2003

Mavis.IMC_StrobeControl_SetConfiguration (IntPtr Camera_Handle, Int32

sStrobeIndex, bool bOnOff, bool bPolarity, Int32 lDelay, Int32 lDuration);

Description:

This function sets the state of specific Strobe Control. This function is workable only

for the Output Ports that are configured to STROBE_SIGNAL. The camera needs be

initialized with IMC_Camera_Init().

Parameters:

Camera_Handle

The handle for MAVIS camera. Use the handle gotten from the

pHandle’ parameter of IMC_Camera_Init().

sStrobeIndex

The register index of Strobe Control and allows value from 0 ~3.

bOnOff

Enable or Disable strobe function. The value can be TRUE for

enable strobe or FALSE for disable strobe.

bPolarity

The signal pulse setting for active Strobe Control and pPolarity

can be one of below settings.

STROBE_CONTROL_LOWACTIVE

STROBE_CONTROL_HIGHACTIVE

By default, the polarity of Strobe Control is

STROBE_CONTROL_HIGHACTIVE.