8-17

J1850 COMMUNICATIONS CONTROLLER

J_CMD

Address:

Reset State:

1F51H

00H

The J1850 command (J_CMD) register determines the messaging type, specifies the number of bytes
to be transmitted in the next message frame, and updates the status of the message transmission in
progress. This byte register can be directly addressed through

windowing. You must write to this

register prior to transmitting every message.

7

0

AUTO

IFR

IGNORE

ABORT

MSG3

MSG2

MSG1

MSG0

Bit

Number

Bit

Mnemonic

Function

7

AUTO

Automatic Transmit Retry

This bit, when arbitration is lost on the first byte of your message, prompts
the transmitter to automatically retry until the byte is successfully
transmitted. Automatic retry applies only to the first byte.

0 = normal operation
1 = enable automatic retry

6

IFR

In-frame Response Indicator

This bit signals that a normalization bit (NB) is to be sent after an end-of-
data symbol is detected on the bus and that the subsequent byte written to
the J1850 transmitter (J_TX) register is an in-frame response (IFR).

0 = standard messaging
1 = next byte written to J_TX is an IFR

5

IGNORE

Ignore Incoming Message

This bit instructs the bus to ignore the incoming message until an EOF
symbol is detected. The bit is cleared after an EOF symbol is detected.

0 = normal operation
1 = ignore incoming message

4

ABORT

Abort Transmission

This bit aborts any transmission in progress and flushes the transmit buffer
(JTX_BUF). To prevent another node from mistakenly assuming that the
last byte was a CRC byte, two extra ‘1’s are appended.

0 = normal operation
1 = abort transmission in progress

3:0

MSG3:0

Message

These four bits specify the number of bytes to be transmitted in the next
message frame. This number includes the header, but not the CRC byte. In
normal messaging, the maximum number of bytes you can transmit in a
message frame is eleven.

MSG3:0

Operation

Purpose

FH

Termination byte

Terminate block transmission

EH

Block transmission Transmit unspecified number of bytes

DH

Reserved

CH

Reserved

B:0H

Normal messaging Transmit specified number of bytes

Figure 8-16. J1850 Command (J_CMD) Register