1 iseries netserver file serving performance – Intel AS/400 RISC Server User Manual

Page 149

Advertising
background image

Chapter 9. iSeries NetServer File Serving Performance

This chapter will focus on iSeries NetServer File Serving Performance.

9.1 iSeries NetServer File Serving Performance

iSeries Support for Windows Network Neighborhood (iSeries NetServer) supports the Server Message
Block (SMB) protocol through the use of Transmission Control Protocol/Internet Protocol (TCP/IP) on
iSeries. This communication allows clients to access iSeries shared directory paths and shared output
queues. PC clients on the network utilize the file and print-sharing functions that are included in their
operating systems. iSeries NetServer properties and the properties of iSeries NetServer file shares and
print shares are configured with iSeries Navigator.

Clients can use iSeries NetServer support to install Client Access from the iSeries since the clients use
function that is included in their operating system. See:

http://www-1.ibm.com/servers/eserver/iseries/netserver

for additional information concerning

iSeries NetServer.

In V5R4, enhancements were made help optimize the performance of the iSeries NetServer, increasing
throughput and reducing client response time. The optimizations allow access to thread safe file systems
in the integrated file system from a new multithreaded file serving job. In addition, other optimizations
have been added and are used when accessing/using files in the “root” (/), QOpenSys, and user-defined
file systems (UDFS). See the iSeries NetServer articles in the iSeries Information Center for more
information.

iSeries NetServer Performance

Server
iSeries partition with 2 dedicated processors having equivalent CPW of 2400.
16384 MB main memory
5-4318 CCIN 6718 18 GB disk drives
2-5700 1000 MB (1 GB) Ethernet IOAs

2

Clients
60 6862-27U IBM PC 300PL Pentium II 400 MHz 512KB L2, 320 MB RAM, 6.4 GB disk drive
Intel® 8255x based PCI Ethernet Adapter 10/100
Microsoft Windows XP Professional Version 2002 Service Pack 1

Controller PC: 6862-27U IBM PC 300PL Pentium II 400 MHz 512KB L2, 320 MB RAM, 6.4 GB disk
drive Intel® 8255x based PCI Ethernet Adapter 10/100
Microsoft Windows 2000 5.00.2195 Service Pack 4

Workload
PC Magazine’s NetBench® 7.0.3 with the test suite ent_dm.tst was used to provide the benchmark data

3

.

IBM i 6.1 Performance Capabilities Reference - January/April/October 2008

©

Copyright IBM Corp. 2008

Chapter 9 - iSeries NetServer File Serving

149

3

The testing was performed without independent verification by VeriTest testing division of Lionbridge Technologies, Inc. ("VeriTest") or Ziff

Davis Media Inc. and that neither Ziff Davis Media Inc. nor VeriTest make any representations or warranties as to the result of the test.
NetBench® is a registered trademark of Ziff Davis Media Inc. or its affiliates in the U.S. and other countries. Further details on the test

2

The clients used 100 MB Ethernet and were switched into the 1 GB network of the server.