Frequency adjustment, 2 frequency adjustment – Icom IC-F3021S User Manual

Page 17

Advertising
background image

6 - 4

6-2 FREQUENCY ADJUSTMENT

Select an adjustment item using [

↑] / [↓] keys, then set to the specifi ed value using [←] / [→] keys on the connected PC’s keyboard.

ADJUSTMENT

ADJUSTMENT CONDITION

MEASUREMENT

VALUE

UNIT

OPERATION

PLL LOCK
VOLTAGE
[RX LVA]

1 • Channel

• Receiving

: CH 1

PC

screen

Click [Reload (F5)] button, then
check the “LVIN” item on the
CS-F3020 ADJ’s screen as below.

3.5 V

[TX LVA]

2 • Channel

• Transmitting

: CH 1

CONVENIENT:

The “PLL LOCK VOLTAGE” can be adjusted automatically.

1: Set the Lock voltage preset ([RX LVA] and [TX LVA]) to “179 (3.15 V).”
2: Push the [ENTER] key on the connected PC’s keyboard.

3 • Channel

• Receiving

: CH 2

PC

screen

Click [Reload (F5)] button, then
check the “LVIN” item on the
CS-F3020 ADJ’s screen.

0.9–1.5 V

(Verify)

4 • Channel

• Transmitting

: CH 2

1.0–1.6 V

(Verify)

REFERENCE
FREQUENCY
[REF]

1 • Channel

: CH 1

Top

panel

Loosely couple a frequency
counter to the antenna connector.

174.000000 MHz

• Connect an RF power meter to the

antenna connector.

• Transmitting

Advertising
This manual is related to the following products: