Ingersoll-Rand 650518 User Manual

Delivery system

Advertising
background image

E

2000

D

PRINTED IN U.S.A.

&

(419) 636-4242

D

FAX (419) 633-1674

INGERSOLL-RAND COMPANY

P.O. BOX 151

D

ONE ARO CENTER

D

BRYAN, OHIO 43506Ć0151

OPERATOR’S MANUAL

650517

RELEASED:

4-10-97

REVISED:

9-15-00

(REV. C)

INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

650517 & 650518

ALSO INCLUDE MANUALS: PH10AĆXĆX HIGH PRESSURE DIAPHRAGM PUMP (PN 97999Ć801), 6661MXĆXĆC DIAPHRAGM PUMP

(PN 97999Ć619), L262X1ĆXXX REGULATOR (PN 100400Ć7), P292X1ĆXXX PIGGYBACK FILTER / REGULATOR (PN 100400Ć8).

1” DIAPHRAGM PUMP, 3:1 RATIO, WITH WALL MOUNT

DELIVERY SYSTEM

650518

SERVICE KITS

Use only genuine ARO replacement parts to assure compatible presĆ

sure rating and longest service life.

Fluid Section Repair Kit 637179.

Air Section Repair Kit 637178.

Refer to the 6661MXĆXĆC Operator's Manual for parts / repair and serĆ

vice information (model 650517).

Refer to the PH10AĆXĆX Operator's Manual for parts / repair and serĆ

vice information (model 650518).

PUMP SYSTEM DATA

System Model

650517(aluminum)

. . . . . . . . . .

650518 (stainless steel)

Basic Pump Model

6661M0Ć2A4ĆC (aluminum)

. . . . .

PH10AĆASSĆSST (stainless steel)

Pump Type

3:1 Ratio, Metallic Air Operated Double

. . . . . . . . . . .

Diaphragm with stainless steel seats

Material

Aluminum

. . . . . . . . . . . . . .

Air Inlet

3/8" Ć 18 N.P.T.F.

. . . . . . . . . . . . . .

Maximum Air Inlet Pressure 100 p.s.i.g. (6.9 bar)

Maximum Outlet Pressure 300 p.s.i.g. (20.4 bar)

Maximum Flow Rate

24 g.p.m. (90.7l/m)

. . . .

Maximum Particle Size

1/8" (3.2 mm)

. .

Maximum Temp. Limits

35_ to 150_F (2_ to 66_C)

. .

Noise Levelh

84.5 db(A) @ 70 psi, 60 cycles per minute.

. . . . . . . . . .

h ThepumpsoundpressurelevelspublishedherehavebeenupdatedtoanEquivalentContinuousSoundLevel

(L

Aeq

) to meet the intent of ANSI S1.13Ć1971, CAGIĆPNEUROP S5.1 using four microphone locations.

GENERAL DESCRIPTION

The 650517& 650718 Wall Mount Pumping System includes fittings,

wall bracket, regulator, siphon tube, gauge and hardware.

The diaphragm pump uses stainless steel balls and seats, and teflon

diaphragms and is designed to be used with waterborne paints. The

gun and low pressure air and material hoses are not included.

OPERATING INSTRUCTIONS

WARNING

DO NOT EXCEED MAXIMUM OPERATING PRESĆ

SURE OF 300 P.S.I. (20.4 BAR) AT 100 P.S.I. (6.9 BAR) AIR INĆ

LET PRESSURE.

WARNING

READ THE PUMP MANUAL FOR ADDITIONAL

OPERATING AND SAFETY PRECAUTIONS AND OTHER IMĆ

PORTANT INFORMATION.

INITIAL SETUP PROCEDURE

Install the connector to the air supply hose.

Attach (17) ground kit to ground lug.

Attach the ground wire to a suitable ground.

Keep containers covered to prevent contamination.

When using an agitator, install a T" at the air inlet or use a sepĆ

arate air supply source.

START-UP

1. Turn the knob on the air regulator counterclockwise to zero p.s.i.

2. Place (11) tube into the container of material.

3. Start the pump to cycle by turning the air regulator knob clockwise.

The pump will cycle several strokes until pressure is built up in the

system, at which time it will stop. Check for any loose fittings or

leakage.

Advertising
This manual is related to the following products:
Table of contents