ISPLAY COLOR SETUP (examples)

Example 1:
Output 1 & Output 2: SSR
Alarm setup: Absolute, Above, Alarm 2 HI Value
"ALR.H" =200, Alarm 1 HI Value "ALR.H"=400
Color Display setup: Normal Color "N.CLR"=Green, Alarm 1
Color "1.CLR"=Amber, Alarm 2 Color "2.CLR"=Red

Display colors change sequences:

GREEN

| RED

| AMBER

•-➤----------------•-----------------------•--------------------------------➤
0 AL2.H=200 AL1.H=400

Example 2:
Output 1: Relay, Set Point 1 = 200,
Output 2: Relay, Set Point 2 = 200
Alarm 1 setup: Deviation, Band, "ALR.H" = 20
Alarm 2 setup: Deviation, Hi/Low, "ALR.H = 10", "ALR.L = 5"
Color Display setup: "N.CLR"=Green, "1.CLR"=Amber,
"2.CLR"=Red

Display colors change sequences:

AMBER | RED | GREEN | GREEN | RED | AMBER

•-➤--------•----------•--------------•--------------•----------•------------➤
0 180 195 200 210 220

READING CONFIGURATION SETUP
(operation example)

Below is a flowchart showing how to navigate through the
submenus of the Reading Configuration menu item by
pressing the front buttons.

Where:

CALC/VALUE = Calculated input based on

the transducer specification
[Without Known Loads (DSBL)]

ACT/VALUE = Actual signal being received

[Known Loads (ENBL)]

MQS3536/1204

SPECIFICATION

Accuracy:

0.03% rdg.

Resolution:

10 / 1 µV process

Linearization Points:

10 points

Temperature Stability:

50 ppm/°C process

Display:

4-digit, 9-segment LED,
10.2 mm (0.40") with red, green and
amber programmable colors

Input Types:

Analog Voltage and Current

Voltage:

0 to 100 mV, 0 to 1 V (+100 mV),
0 to 10 Vdc

Input Impedance:

10 MΩ for 100 mV
1 MΩ for 1 or 10 Vdc

Current:

0 to 20 mA(5 Ω load)

Output 1:

Relay 250 Vac @ 3 AResistive Load,
SSR, Pulse, Analog Voltage and Current

Output 2:

Relay 250 Vac @ 3 AResistive Load,
SSR, Pulse

Options: Communication

RS-232 / RS-485 or
Excitation: 5 Vdc @ 40 mA,
10 Vdc @ 60 mA

Exc. not available for Low Power Option

Line Voltage/Power:

90 - 240 Vac ±10%, 50 - 400 Hz*,
or 110 - 375 Vdc, 4 W

* No CE compliance above 60 Hz

Low Voltage Power Option:

12 - 36 Vdc, 3 W**

** Units can be powered safely with 24 Vac

but No Certification for CE/UL are claimed.

Dimensions:

25.4 H x 48 W x 126.3 D mm
(1.0 x 1.89 x 5")

Weight:

127 g (0.28 lb)

Approvals:

UL, C-UL, CE per EN61010-1:2001

d

d

b

b

• • •

d

d

b

d

b

b

d

d

b

b

• • •

d

b

d

d

d

d

bc

d

d

d

d

d

d

d

d

• • • • • • • •

a

a

a

bc

bc

bc

bc

bc

WARRANTY/DISCLAIMER

OMEGAENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of
one (1) year from the date of purchase. In addition to OMEGA’s standard warranty period, OMEGA Engineering will
extend the warranty period for four (4) additional years if the warranty card enclosed with each instrument is
returned to OMEGA.

If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will
issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA,
if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply
to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing,
operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit
shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive
corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating
conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to
contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither
assumes responsibility for any omissions or errors nor assumes liability for any damages that result from
the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA
warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO
OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED,
EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION
OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with
respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or
otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event
shall OMEGA be liable for consequential, incidental or special damages.

CONDITIONS: Equipment sold by OMEGAis not intended to be used, nor shall it be used: (1) as a “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications
or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application,
used on humans, or misused in any way, OMEGAassumes no responsibility as set forth in our basic
WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless
from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGACustomer Service Department. BEFORE
RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR)
NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPA RTMENT (IN ORDER TO AVOID PROCESSING
DELAYS). The assigned AR number should then be marked on the outside of the return package and on any
correspondence.

The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in
transit.

FOR WARRANTY RETURNS, please have the
following information available BEFORE
contacting OMEGA:
1.

Purchase Order number under which the product
was PURCHASED,

2.

Model and serial number of the product under
warranty, and

3.

Repair instructions and/or specific problems
relative to the product.

FOR NON-WARRANTY REPAIRS, consult OMEGA for
current repair charges. Have the following information
available BEFORE contacting OMEGA:
1.

Purchase Order number to cover the COST of the
repair,

2.

Model and serial number of product, and

3.

Repair instructions and/or specific problems
relative to the product.

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords
our customers the latest in technology and engineering.

OMEGAis a registered trademark of OMEGAENGINEERING, INC.

© Copyright 2004 OMEGAENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without
the prior written consent of OMEGAENGINEERING, INC.

PATENT AND TRADEMARK NOTICE: This product is covered by one or more of the following patents: U.S. Pat.
No. Des. 336,895; 5,274,577; 6,243,021 / CANADA 2052599; 2052600 / ITALY 1249456; 1250938 / GERMANY DE
41 34398 C2 / SPAIN 2039150; 2048066 / UK Patent No. GB2 249 837; GB2 248 954 / FRANCE BREVET NO. 91
12756. The “Meter Bezel Design” is a trademark of Newport Electronics, Inc. USED UNDER LICENSE. Other U.S.
and International Patents pending or applied for.

This device is marked with the international caution symbol. It is important to read the
Setup Guide before installing or commissioning this device, as the guide contains important
information relating to safety and EMC.

WARNING: These products are not designed for use in, and should not be used for, patient-
connected applications.

It is the policy of OMEGAto comply with all worldwide safety and EMC/EMI regulations that apply.
OEMGAis constantly pursuing certification of its products to the European New Approach Directives.
OMEGAwill add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGAEngineering, Inc.
accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.

TRADEMARK NOTICE:

®

,

omega.com

®

,

,

and

®

are Trademarks of

OMEGAENGINEERING, INC.

®

USA

MADE IN

CNiS32

Process / Strain Gauge

Controller

Servicing North America:

USA:

One Omega Drive, P.O. Box 4047

ISO 9001 Certified

Stamford CT 06907-0047

TEL: (203) 359-1660

FAX: (203) 359-7700

e-mail: [email protected]

Canada:

976 Bergar

Laval (Quebec) H7L 5A1

TEL: (514) 856-6928

FAX: (514) 856-6886

e-mail: [email protected]

For immediate technical or application assistance:

USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA

®

Customer Service: 1-800-622-2378 / 1-800-622-BEST

®

Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN

®

Mexico and

TEL: (001)800-TC-OMEGA

®

FAX: (001) 203-359-7807

Latin American:

En Español: (001) 203-359-7803

e-mail: [email protected]

Servicing Europe:

Benelux:

Postbus 8034, 1180 LA Amstelveen, The Netherlands

TEL: +31 20 3472121

FAX: +31 20 6434643

Toll Free in Benelux: 0800 0993344

e-mail: [email protected]

Czech Republic:

Frystatska 184, 733 01 Karviná

TEL: +420 59 6311899

FAX: +420 59 6311114

e-mail: [email protected]

France:

11, rue Jacques Cartier, 78280 Guyancourt

TEL: +33 1 61 37 29 00 FAX: +33 1 30 57 54 27

Toll Free in France: 0800 466 342

e-mail: [email protected]

Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany

TEL: +49 7056 9398-0

FAX: +49 7056 9398-29

Toll Free in Germany: 0800 639 7678

e-mail: [email protected]

United Kingdom: One Omega Drive

ISO 9002 Certified

River Bend Technology Centre

Northbank, Irlam Manchester M44 5BD United Kingdom

TEL: +44 161 777 6611 FAX: +44 161 777 6622

Toll Free in England: 0800 488 488

e-mail: [email protected]

OMEGAnet

®

On-Line Service

www.omega.com

Internet e-mail

[email protected]

®

®

Advertising