16

SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

CAM TIMER OPERATION FOR LT-1 (CONTINUED)

CAM 6: Cam 6 is an adjustable cam and controls the sanitizer pump.

FUNCTION: The sanitizer pump cam works off the normally closed contacts of cam 6. This requires the switch to be held open
by the cam and allowed to drop into the notch to operate the pump.

SETTINGS: The left side of cam 6 must be set to drop in just past the starting point of the wash cam. The adjustment for san-
itizer volume must be made with the right side of the cam.

CAM 7: Cam 7 is an adjustable cam and controls the detergent pump.

FUNCTION: The detergent pump cam works off the normally closed contacts of cam 7. This requires the switch to be held open
by the cam and allowed to drop into the notch to operate the pump.

SETTINGS: The left side of cam 7 must be set to drop in just past the starting point of the wash cam. The adjustment for deter-
gent volume must be made with the right side of the cam.

CAM 8: Cam 8 is an adjustable cam and controls the rinse aid pump.

FUNCTION: The rinse aid pump cam works off the normally closed contacts of cam 8. This requires the switch to be held open
by the cam and allowed to drop into the notch to operate the pump.

SETTINGS: The left side of cam 8 must be set to drop in just past the starting point of the wash cam. The adjustment for rinse
aid volume must be made with the right side of the cam.