7.0 Electrical Wiring Instructions

IMPORTANT NOTICE: The electrical wiring of this spa must meet
the requirements of the National Electrical Code/USA (NEC) and any
applicable state or local codes. The electrical circuit must be installed
by a qualified electrician and approved by a local building/electrical
inspection authority.

1. Convertible 120/240V Power Models:

120V “Plug-in” Operation: This spa must operate on the supplied
120V GFCI cord at its original length or must be hard-wired for
longer runs. NEVER USE AN ExTENSION CORd FOR ANy REA-
SON!

Export J-210 / J-220 1-Pump Models (50Hz)

230V/20A*

230V/30A**

Voltage:

230 VAC

230 VAC

# of Wires:

3

3

Frequency:

50Hz

50Hz

Current Draw:

15A

21A

Circuit Breaker:

20A

30A

* In the 20A configuration, the heater will not operate while the jets

pump is running in high speed.

This is the factory setting.

** In the 30A configuration, the heater will operate while the jets pump

is running in high speed.

Export J-230 2-Pump Model (50Hz)

230V/20A*

230V/30A**

230V/40A***

Voltage:

230 VAC

230 VAC

240 VAC

# of Wires:

3

3

3

Frequency:

50Hz

50Hz

50Hz

Current Draw:

15A

23A

2A

Circuit Breaker:

20A

30A

40A

*

In 20A configuration, the heater will not operate while either jets

pump is running in high speed.

This is the factory setting. Note:

pump 2 runs only in high speed.

** In the 30A configuration, the heater will operate while one jets

pump is running in high speed. Note: pump 2 runs only in high

speed.

*** In 40A configuration, the heater will operate while both jet pumps

are running in high speed. Note: pump 2 runs only in high speed.