0 circuit board diagrams, Dedicated power models (60 hz) – Jacuzzi J - 315 User Manual

Page 46

Advertising
background image

42

J-300

16.0 Circuit Board Diagrams

16.1 north american J-335, J-345, J-355, J-365 and J-375

Dedicated power models (60 Hz)

This wiring diagram is used for all North American, 240V (60 Hz)

dedicated power models.

Optional Stereo

And

Power Supply (not of

fered on J-325 Models)

Power Supply

O

ZO

N

AT

O

R

(O

PT

IO

N

AL

)

O

3

GRN

TB1

Standard 240 V

AC, 3-W

ire Connection (60Hz, 1-Phase Service)

USE COPPER CONDUCT

ORS ONL

Y. WIRE SIZE MUST

BE

APPROPRIA

TE PER NEC

AND/OR LOCAL

CODES

RED

RED

J6

BLK J5

WHT

WHT

WHT

RED

BLK

BLK

BLK

WHT

BLK

RED

RED

BLK

BLK

BLK

2

1

FLOW SWITCH

HI - LIMIT

/ FREEZE SENSOR

TEMPERA

TURE SENSOR

J1

J2

J3

F1 30A, 250V SC-30

PU

M

P

1

PU

M

P

2

TR

AN

SF

O

R

M

ER

24

0

VA

C

F1

JP1

4 2

3 1

6

5

8

7

7

6

2

4

HI

HI

LO

C

C

on

tro

l P

an

el

J4

CIRC. PUMP

J20

K1

K2

K3

K4

K5

K6

K7

K8

J21

J1

1

J12

J13

J14

J15

J16

J17

J18

J19

J7

J8

J9

J10

Logic Jumper Settings (Factory Defaults Shown) JP1 1-2 ON =

40A

Logic

JP1 1-2 OFF =

50A

Logic (Factory Default Setting)

JP1 3-4 ON =

2 Pump Operation

JP1 3-4 OFF =

1 Pump Operation

JP1 5-6 ON =

60A

Logic (Remove JP1 1-2 Jumper)

JP1 5-6 OFF =

Leave Of

f for 40A

or 50A

Logic

JP1 7-8 ON =

Celsius

Temperature Display

JP1 7-8 OFF =

Fahrenheit

Temperature Display

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1.

This device may not cause harmful

interference.

2.

This device must accept any inteferenc

e

received including interference that ma

y

cause undesired operation.

Heater 5.5 kW 240 V

AC

X

X

W

W

12 V

AC From

Transformer

12 V

AC Output to

W

aterfall Light/ Footwell Light Controller

Blue wires 12 V

AC

constant voltage (connects to the yellow wires on the

transformer)

Light DCU

W

aterfall and Footwell

lights can connect to any plug on the DCU (P/N 6560-134)

Yellow Connector

Control Panel

A

A

6560-134

Advertising
This manual is related to the following products: