45

QUICK ALIGN.

PC

VIDEO

VOLUME

PRESET

HIDE

ENTER

MENU

EXIT

FREEZE

OPERATE

V-KEYSTONE H-KEYSTONE

SCREEN

DIGITAL

ZOOM

FOCUS

W

S

PRESET

HIDE

EXIT

press for
2 seconds

EXIT

PRESET

HIDE

VOL( )

Press as per normal

Press for 2 seconds or more

Replacing the Lamp

1.

Insert the main plug. The projector will go into the stand

by mode.

ON: STAND BY indicator lights up.

2.

Press the EXIT, HIDE, PRESET buttons on the remote

control sequentially, then press VOL

ª

for 2 seconds or

more.

The STAND BY and OPERATE indicators alternately blink about
every approx.3 seconds. After blinking stops, “Lamp time” resets
and the projector returns to the stand-by state (STAND BY indicator
lights up).

Resetting the lamp time

After installing a new lamp, reset the “Lamp time” counter inside the projector.
When this is done, a new count will start.
If the display of the accumulated lamp time has reached 2000 hours, the projector will not work (lamp does not light up) unless the
lamp time is reset.

To ensure the lamp time has been reset.

The Lamp time can be checked via the “Lamp time” item in the “Infor-
mation” menu. (

☞ page 32, 33, 34, 40)

Caution for reset work

Reset the “Lamp time” only when you have replaced the lamp.
Never reset it while the lamp is still in use, otherwise the approxi-
mate standard for gauging replacement time may be inaccurate, lamp
performance may suffer and lamp blow-out may also occur.