Warning indication – JVC DLA-SX21SU User Manual

Page 51

Advertising
background image

51

About warning indicators

If something abnormal has occurred in the projector, the warning mode sets in and the type of abnormality will be indicated by a
combination of indicators displayed on the control panel as shown in the following table.
The projector will then automatically stop projection and run the cooling fan for about 90 seconds.

Warning Indication

Action to be taken upon warning indications

Please follow the procedures below.

For No.1-3

No.1 : Unplug from the main power outlet and restart according to the basic operation procedures.
No.2 : After checking if a shock (such as from knocking) has not ocurred during operation, unplug from the main power outlet

and restart according to the basic operation procedures.

No.3 : Unplug from the main power outlet and restart according to the basic operation procedures.

For No.4-7

After the STAND BY indicator lights up, pull out the power cord and check the following items one-by one.
No.4 : Ensure that the lamp is correctly set in place. Restart according to the basic operation procedures.
No.5 : Check that nothing is blocking the air inlets, and wait until the inside cools down. Restart according to the basic operation

procedures.

No.6 : Check the ambient temperature. If it is normal, leave the projector until it cools down. Restart according to the basic

operation procedures.

No.7 : Leave the projector until it cools down. Restart according to the basic operation procedures.

If the same warning indication is observed again despite the instructions above, wait for the cooling fan to stop, check that the
STAND BY indicator on, then unplug the power cord and call your dealer for repair.

Indicator

LAMP

TEMP

STAND BY

OPERATE

1

Blink

Blink

The light-source lamp does not light up and projection cannot be done.

2

Blink

Blink simultaneously

Blink

The light-source lamp suddenly goes off during projection.

3

Blink

Blink

Circuit operation is abnormal.

4

Blink

Blink alternately

Blink

The light-source lamp is misfitted.

5

Blink

The internal temperature is abnormally high.

6

Blink

Blink

The temperature at the air inlets has risen abnormally high.

7

Blink

Blink

Blink

Blink

The cooling fan has stopped. (Fan locked)

* For details on individually blinking indicators, please see page 43.

Warning

No.

Advertising
This manual is related to the following products: