Warranty information, Troubleshooting 25 – Stellar Industries V480 User Manual

Page 29

Advertising
background image

Troubleshooting 25

Problem

Air Output low:

(Air Pressure Low)

Air pressure too low:

Air pressure too high:

High crankcase oil usage:

Blowing oil from crankcase

breather:

Compressor will not stop:

Possible Cause

Dirty air filter.

Insufficient torque on head bolts.

Intake reed valves malfunction.

Air line leaking.

Air consumption exceeds Compressor

capacity.

Air pressure switch set incorrectly.

Intake or exhaust reed valves

damaged.

Pressure switch not functioning

correctly.

Internal contamination.

Pressure switch not adjusted

correctly.

External oil leaks.

Oil level too high.

Piston rings worn or broken.

Oil level in crankcase too high.

Blown head gasket.

Piston rings worn or broken.

Hole in piston.

Air pressure switch set incorrectly .

Leaking air hoses or fittings.

Inspect and clean filter.

Tighten bolts to required torque.

If air back-flows from air filter, reed valve is faulty

and needs to be replaced.

Inspect and tighten loose hoses.

Check air demand for items using the air supply.

Readjust high pressure setting.

Inspect and replace.

Inspect and clean.

Inspect and clean.

Readjust to lower pressure.

Inspect and repair gaskets or seals.

Check oil level and drain if needed.

Replace rings.

Check oil level and drain.

Replace gasket.

Replace ring.

Replace piston.

Check points and setting on switch.

Tighten all fittings and hoses.

Advertising
This manual is related to the following products: