Sony XCD-V60 User Manual

Page 23

Advertising
background image

Co
nt

rol

23

Actual control can be carried out by setting registers
from F0F00800 onward.
ddd indicates the control value expressed as a 12 bit
hexadecimal number.
xxx indicates that any setting made will be ignored.

Brightness control

AE reference control

Sharpness control

White balance control

Hue (G level) control

Saturation control

Gamma control

Shutter (exposure time) control

Gain control

Trigger control

Trigger Delay control

Address

Data

F0F00800

82000ddd

Adjusts the black level.

Address

Data

F0F00804

82000ddd

Sets the AE reference value.

Address

Data

F0F00808

82000000

Sets to the soft image quality.

82000007

Sets to the sharp image quality.

Address

Data

F0F0080C

82BBBRRR

Adjusts the white balance
manually.

83xxxxxx

Adjusts the white balance
automatically.

86xxxxxx

Perform the one-push auto
white balance function.

Address

Data

F0F00810

82000ddd

Sets the green video level.

Address

Data

F0F00814

82000ddd

Adjusts the color intensity.

Address

Data

F0F00818

82000000

Sets Gamma to OFF.

82000001

Reverses the black and white.

82000002

Sets the gamma curve
equivalent to 0.7.

82000003

Sets an optional gamma curve
by a user. (See “LUT.”)

Address

Data

F0F0081C

82000ddd

Controls shutter using the
manually set relative value.

83000xxx

Sets the shutter control to
AUTO.

C2000xxx

Controls shutter using the
absolute value.

F0F00978h
(To obtain
this address,
see “The
formula for
absolute
value shutter
control
register
address” on
page 24
.)

Determines
the optional
value using
the 32-bit
floating-
point format.

After F0F0081C has been set
to the absolute value control,
set the exposure time using
this register.

Address

Data

F0F00820

82000ddd

Set Gain manually.

83000xxx

Set Gain to AUTO.

Address

Data

F0F00830

82000000

Sets to Hardware Trigger
Mode0.

82010000

Sets to Hardware Trigger
Mode1.

820E000d

Sets to Hardware Trigger
Mode14.

820F000d

Sets to Hardware Trigger
Mode15.

82E00000

Sets to Software Trigger
Mode0.

82E10000

Sets to Software Trigger
Mode1.

82EE000d

Sets to Software Trigger
Mode14.

82EF000d

Sets to Software Trigger
Mode15.

F0F0062C

80000000

Outputs a software trigger. In
Trigger Mode0, automatically
resets to 0 when exposure
ends.

00000000

In Trigger Mode1, ends
exposure if “0” is set.

Address

Data

F0F00834

82000ddd

Sets Trigger Delay.

Advertising