Caution, Window requirements, Storm window requirements – Sharp AF-Q100PX User Manual

Page 6: Remove the air conditioner from the case

Advertising
background image

WINDOW REQUIREMENTS

These instructions are for a standard

double-hung window. You will need to
modify them for other types of windows.

CAUTION:

If the sill support

bolts do not contact the window sill, or
if you have a window without a sill, you
must order accessory kit RAK87 to
properly install this air conditioner.

All supporting parts must be secured

to firm wood, masonry or metal.

The electrical outlet must be within

reach of the power cord.

STORM WINDOW REQUIREMENTS

A storm window frame will not allow the air
conditioner to tilt toward the outside, and
will keep it from draining properly. To adjust
for this, attach a piece of wood to the sill.
WOOD PIECES –
WIDTH:
2

LENGTH: Long enough to fit inside the
window frame.
THICKNESS: To determine the thickness,
place a piece of wood on the sill to make
it 1/2

″ higher than the top of the storm

window frame or the vinyl frame.
Attach securely with nails or screws
provided by the installer.

1/2

″ higher

than storm
window
frame

Storm window
frame

Wood

Sill

1/2

″ higher

than vinyl frame
(on some windows)

Vinyl frame

REMOVE THE AIR CONDITIONER
FROM THE CASE

Remove and save the 2 screws from the
lower sides of the front grille.

Grasp the lower corners of the grille while
pressing in on the case sides with your
finger tips. Pull out to release and lift it up.
NOTE: Do not pull the bottom edge
toward you more than 3

″ or you may

damage the tabs of the grille.

Remove the ground screw from each side
of the case. Keep them in a safe location.

A

B

D

Remove 4 screws of control panel from
front panel.

C

Advertising