5 checking the internal temperature (lom -t), Checking the internal temperature, Lom -t – Sun Microsystems Netra 120 User Manual

Page 128: 5 checking the internal temperature ( lom -t )

Advertising
background image

9-4

Sun Fire V120 and Netra 120 Server User’s Guide • December 2001

To check the status of the supply rails and internal circuit breakers, type:

9.1.5

Checking the Internal Temperature (

lom -t

)

To check the internal temperature of the system and also the system’s warning and
shutdown threshold temperatures, type:

# lom -v

Supply voltages:

1 5V status=ok

2 3V3 status=ok

3 +12V status=ok

4 -12V status=ok

5 VDD status=ok

6 +3VSB status=ok

7 BATTERY status=ok

System status flags (circuit breakers):

1 SCSIA TERM status=ok

2 USB status=ok

3 SCC status=ok

# lom -t

System Temperature Sensors:

1 enclosure 25 degC : warning 67 degC : shutdown 72 degC

System Over-temperature Sensors:

1 cpu status=ok

#

Advertising