2 installing the new system board, Installing the new system board – Sun Microsystems Netra 120 User Manual

Page 169

Advertising
background image

Chapter 11

Replacing a Server or Replacing Individual Components

11-15

11.6.2

Installing the New System Board

Note –

The system board contains a jumper (JP8) that identifies the hardware to the

system software as either a Sun Fire V120 or a Netra 120. The factory default setting
for JP8 on FRU replacement system boards (F375-3064 and F275-3065) identifies
them as Sun Fire V120s. Before installing a new system board, make sure that the
setting for JP8 is correct for the model of system you are installing it into. To check
the jumper settings, see Appendix D. Do not alter any other jumper settings.

1. Check that the setting for jumper JP8 on the new system board is correct for the

model of server you are installing it into (see Appendix D).

2. Insert the new system board at an angle, and locate it so that the SCSI, Ethernet,

and serial connectors are firmly positioned in their slots at the rear of the chassis.

3. Now position the system board on the alignment stand-off between the PSU fan

and hard disk drive bay 1 (see

FIGURE 11-7

).

4. Insert the SCSI pillars (see

FIGURE 11-7

) and replace their screws loosely.

5. Insert all system board fixing screws loosely (see

FIGURE 11-7

). Do not put any

screws in the holes for the PCI card slide retainer.

6. Tighten up the SCSI pillars, then tighten all the other screws.

7. Replace the PCI card slide retainer.

8. Replace the DIMMs that you removed from the old system board (see Section 4.5,

“Installing and Removing Memory” on page 4-9).

9. Replace the rear fan assembly (see Section 11.8, “Replacing the Rear Fan

Subassembly (Fans 1 and 2)” on page 11-19).