Specifications, E-22 – Sharp ENGLISHFRANAISESPAOL KC-860U User Manual
Page 24
E-22
SPECIFICATIONS
Model
KC-860U
Power supply
120 V 60 Hz
Fan Speed Adjustment
MAX
MED
LOW
CLEAN AIR
Fan Speed (CFM)
272
124
42
Rated Power (W)
87
14
4.8
Noise Level (dBA)
54
37
19
CLEAN AIR &
HUMIDIFY
Fan Speed (CFM)
219
124
74
Rated Power (W)
50
16
9
Noise Level (dBA)
49
37
28
Humidifi cation (pints/hour)*2
1.5
0.9
0.6
Recommended Room Size *1
341 sq.ft (31.7 m
2
)
CADR (Dust/Smoke/Pollen)
231 / 220 / 245
Water Tank Capacity (gallon)
1.14
Sensors
Dust/Temperature & Humidity
Filter type
Dust collection
True HEPA with Microbial control
Deodorization
Washable Deodorizing
Cord Lenght
6.5ft (2.0m)
Dimensions
398 (W) × 288 (D) × 627 (H)
15
3
/
4
in (W) x 11
3
/
8
in (D) x 24
3
/
4
in (H)
Weight
25.8 lbs (11.7 kg)
*1 •
The Recommended Room Size is appropriate for operating the unit of maximum fan speed.
*2 •
Humidifi cation Amount changes in accordance with indoor and outdoor temperature and humidity.
Humidifi cation Amount increases as temperatures rise or humidity decreases.
Humidifi cation Amount decreases as temperatures decrease or humidity rises.
Standby Power
In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product
consumes about 0.4 W of standby power.
For energy conservation, unplug the power cord when the unit is not in use.