1-12

E

1-11

Setting RS-422A/RS-485 termination

1

2

As it is shown in the structure map, when Controller and RS-422A/RS-
485 is connected it should be terminated according to the Cable feature
of impedance on the each end of the transmitting line to transfer the
signals in long distance by controlling the reflection of the signals to the
lowest.

<RS-485 Half Duplex Organization>

n < 32

Termination

SW1-ON

Division

Termination: using numbers 1 and 2 PIN, turn to ON and it will be terminated.

<RS-422A/RS-485 Full Duplex Organization>

Division

Division
SW1-ON
SW2-ON

n < 32

INITIAL SETTING

CAMERA ADDRESS SETUP

Use SW701, SW702, or 703 for Camera Address setup. You may allocate
up to 255 addresses by using SW701 to set the 3rd digit, SW702 the 2nd
digit, and SW703 the 1st digit.
EX) In case of Camera Address 1, see the following figure for setup.

Setting communication Protocol

Use number 1~4 PIN of SW704 to set communication Protocol.

Baud Rate Setting

Use PIN 5 and 6 of SW704.

SW701

SW702

SW703

1 2

3 4 5 6 7 8

ON

OFF

BAUD RATE

4800 BPS

9600 BPS

19200 BPS

38400 BPS

PIN 5

ON

OFF

ON

OFF

PIN 6

ON

ON

OFF

OFF

A : SAMSUNG HALF
B : SAMSUNG FULL

PIN1

PIN2

PIN3

PIN4

A

OFF

OFF

OFF

OFF

B

ON

OFF

OFF

OFF

C

OFF

ON

OFF

OFF

D

ON

ON

OFF

OFF

E

OFF

OFF

ON

OFF

F

ON

OFF

ON

OFF

G

OFF

ON

ON

OFF

H

ON

ON

ON

OFF

I

OFF

OFF

OFF

ON

J

ON

OFF

OFF

ON

K

OFF

ON

OFF

ON

L

ON

ON

OFF

ON

M

OFF

OFF

ON

ON

N

ON

OFF

ON

ON

O

OFF

ON

ON

ON

P

ON

ON

ON

ON

PIN

Comp

(x100) (x10) (x1)

SW704

ON 1 2 3 4 5 6 7 8

SW701 SW702 SW703

SEE INSTRUCTION MANUAL

(BOTTOM VIEW)