880 SERIES

3.3

important Additional CSA Safety instructions (Canada Only)

When using this electrical equipment, basic safety precautions should

always be followed, including the following:

1.

reAd ANd FOLLOW ALL iNSTrUCTiONS.

2. A green colored terminal or a terminal marked G, Gr, Ground,

Grounding or the symbol* is located inside the supply termi-

nal box or compartment. To reduce the risk of electric shock, this

terminal must be connected to the grounding means provided in the

electric supply service panel with a continuous copper wire equiva-

lent in size to the circuit conductors that supply this equipment (*IEC

Publication 417, Symbol 5019).

3. At least two lugs marked “Bonding Lugs” are provided on the exter-

nal surface or on the inside of the supply terminal box/compartment.

To reduce the risk of electric shock, connect the local common bond-

ing grid in the area of the spa to these terminals with an insulated or

bare copper conductor not smaller than No. 6 AWG (10 mm²).

4. All field installed metal components such as rails, ladders, drains or

other similar hardware within 10 feet (3m) of the spa shall be bonded

to the equipment grounding buss with copper conductors not smaller

than No. 6 AWG (10 mm²).

5.

SAVe THeSe iNSTrUCTiONS.