T0con – Samsung S3F80JB User Manual

Page 108

Advertising
background image

S3F80JB

CONTROL REGISTERS

4-41

T0CON

— Timer 0 Control Register

D2H Set 1 Bank0

Bit

Identifier

.7 .6 .5 .4 .3 .2 .1 .0

Reset Value

0 0 0 0 0 0 0 0

Read/Write

R/W R/W R/W R/W R/W R/W R/W R/W

Addressing Mode

Register addressing mode only

.7 – .6

Timer 0 Input Clock Selection Bits

0 0

f

OSC

/4096

0 1

f

OSC

/256

1 0

f

OSC

/8

1

1

External clock input (at the T0CK pin, P3.1 or P3.2)

.5 and .4

Timer 0 Operating Mode Selection Bits

0

0

Interval timer mode (counter cleared by match signal)

0

1

Capture mode (rising edges, counter running, OVF interrupt can occur)

1

0

Capture mode (falling edges, counter running, OVF interrupt can occur)

1

1

PWM mode (Match and OVF interrupt can occur)

.3

Timer 0 Counter Clear Bit

0

No effect (when write)

1

Clear T0 counter, T0CNT (when write)

.2

Timer 0 Overflow Interrupt Enable Bit (note)

0

Disable T0 overflow interrupt

1 Enable

T0

overflow

interrupt

.1 Timer

0

Match/Capture Interrupt Enable Bit

0

Disable T0 match/capture interrupt

1

Enable T0 match/capture interrupt

.0 Timer

0

Match/Capture

Interrupt Pending Flag Bit

0

No T0 match/capture interrupt pending (when read)

0

Clear T0 match/capture interrupt pending condition (when write)

1

T0 match/capture interrupt is pending (when read)

1

No effect (when write)

NOTE: A timer 0 overflow interrupt pending condition is automatically cleared by hardware. However, the timer 0

match/capture interrupt, IRQ0, vector FCH, must be cleared by the interrupt service routine (S/W).