S3F80JB

COMPARATOR

14-3

COMPARATOR OPERATION

The comparator compares input analog voltage at CIN0–CIN3 with an external or internal reference voltage
(V

REF

) that is selected by the CMOD register. The result is written to the comparison result register CMPREG at

address EAH, Set1, Bank1. The comparison result at internal reference is calculated as follows:

If "1"

Analog input voltage

≥ V

REF

+ 150 mV

If "0"

Analog input voltage

≤ V

REF

– 150 mV

To obtain a comparison result, the data must be read out from the CMPREG register after V

REF

is updated by

changing the CMOD value after a conversion time has elapsed.

Comparision Time

(CMPCLK x8)

Comparision

Start

Comparision

End

Unknown

1

1

Unknown

0

Analog Input Voltage (CIN0-3)

Reference Voltage (V

REF

)

Comparator Clock

(fosc/16, fosc/128)

Comparision Result

(CMPREG)

Figure 14-2. Conversion Characteristics