Port selection – Samsung 460DXN User Manual

Page 122

Advertising
background image


Main Icons

Select Button

Remocon

Info Grid

Safety Lock

Display Selection

Port Selection

Control Tools

1. Use the main icons to switch into each screen.

2. Allows you to enable or disable the remote control signal receiving function of the display unit.

3. Set the Safety Lock function.

When setting the Lock function, you can only operate power and lock buttons on the remote control and set.

4. The setting for the PC Serial Port can change. The original value is COM1.

5. Click Select all or Clear to select or clear all displays.

6. Use Grid to view brief information on selected display.

7. Select a display from Display Selection.

8. Use Control Tools to control displays.

<Note> The remote control Enable/Disable function operates whether or not the power is On/Off, and this

applies to all displays connected to the MDC. However, regardless of the status at the time the MDC is
shut down, the remote control signal receiving function of all displays is initialized to Enable when the
MDC is closed.

Port Selection

Advertising
This manual is related to the following products: