Chapter 2. Troubleshooting the RXT150

21

Resetting the RXT150 with the Serial Interface

Before You Begin

Before using the serial interface, make sure that:

• You have a properly configured terminal emulator, such as TeraTerm.

(HyperTerminal is not recommended for use with the RXT-150.)

• You have a standard DB9 serial cable.

• The terminal emulation settings are set to:

• 115200 bps

• 8 data bits

• No parity

• 1 stop bit

• No flow control

Resetting the RXT150

1. Connect a serial cable from the host to the RXT150.

2. Open TeraTerm, or a similar terminal emulation program.

(HyperTerminal is not recommended for use with the RXT150.

3. Press the Enter key on your keyboard to display a command prompt.

4. Type

cnDiagnosticShell

, then press the Enter key on your keyboard. The

RXT Drive Diagnostics Main Menu (Figure 2-10) displays.

5. Type

6

, then Enter; a prompt appears, asking you to confirm the reset.

6. To confirm the reset, type

Y

, then Enter. In less than 30 seconds, the RXT150

reboots; it should come to ready mode again in the normal time frame of 20
seconds to two minutes.

To escape the reset process, type

N

, then Enter.

Figure 2-12

The RXT Drive Diagnostics Main Menu.