Preparing to replace a failed disk drive – Spectra Logic RXT150 User Manual

Page 24

Advertising
background image

Chapter 3. Troubleshooting RXT Media

24

Preparing to Replace a Failed Disk Drive

To prepare for the replacement of the failed disk drive, follow these steps.

1. Log on to the RXT150 Web interface

2. Select Maintenance > Tools > Get RXT Media Pack Drive Status; the Get RXT

Media Pack Drive Status Utility screen displays (Figure 3-2).

The display indicates the number of disk drives in the pack and their serial
numbers.

The expected mapping of the disk drives should be green (Optimal). If you have
a disk drive error, the disk drive background is Red (Failed), Yellow (Missing),
or Orange (Incorrect Size).

3. Write down the serial number of the disk drive with a problem.

4. Contact SpectraGuard Support, as outlined on page 37.

5. Proceed only after support has directed you to replace a failed drive, and after

you have procured an approved drive from Spectra Logic.

6. Shut down all backups to the RXT150.

7. Eject the RXT media from the RXT150.

8. Depending on your RXT media type:

• For Silver or Green RXT media, proceed to Replacing a Disk Drive in Silver

and Green RXT Media on page 25.

• For Gold RXT Media, proceed to Replacing a Disk Drive in Gold RXT Media

on page 34.

Figure 3-2

The Get RXT Media Pack Drive Status Utility screen.

Drive
Serial
Number

12 disk drives
in this pack
(Gold Media)

Color
indicates
status