Controlling the Monitor with a PC (RS-232C)

Others

Function

Command Direction

Parameter

Reply

Control/Response contents

*

SCREEN SIZE (PC)

WIDE

WR

1-5

1-5 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2

B

SCREEN SIZE (AV)

WIDE

WR

1-5

1-5 1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: Dot by Dot

B

VOLUME

VOLM

WR

0-31

0-31

B

MUTE

MUTE

WR

0-1

0-1 0: OFF, 1: ON

-

INFORMATION

MODEL

INF1

R

Value

A

SERIAL NO

SRNO

R

Value

BRIGHT

VLMP

WR

0-31

0-31 Brightness

B

TEMPERATURE SENSOR

DSTA

R

0 Internal temperature normal

A

1 Internal temperature abnormal (Standby mode)
2 Internal temperature abnormal (Temperature is normal now, but it was

abnormal during operation.)

3 Internal temperature abnormal (Brightness of the backlight decreases.)
4 Temperature sensor abnormal

TEMPERATURE ACQUISITION

ERRT

R

Value Temperature at temperature sensors 1 through 3 are returned in the

following forms:
[Sensor 1], [Sensor 2], [Sensor 3]
Indicates a temperature sensor abnormality when “126” is returned.

A

CAUSE OF LAST STANDBY MODE

STCA

W

0

Initialization

A

R

0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power “OFF” by the main power switch
3 Standby mode by RS-232C or LAN
4 Waiting mode by No Signal (Incl: VESA DPMS/DMPM)
6 Standby mode by abnormal temperature
8 Standby mode by SCHEDULE setting