Model D4137

2 HP 110V Magnetic Switch

Instruction Sheet

Phone #: (360) 734-3482 • Online Tech Support: [email protected] • Web: www.shopfox.biz

BLACK
GREEN
RED

COLOR KEY

Bk

Gn

Rd

YELLOW

3

L2

5

L3

13

NO

2

T1

4

T2

6

T3

14

NO

TEST

TRIP IND.

97 NO

98 NO

95 NC

96 NC

2

T1

4

T2

6

T3

O R

54

NO

NO

53

ON

OFF

RESET

2 HP 110V Motor

110 Volt

Single-Phase

Power Source

M

A

1

L1

TECO

CU-

16

Ground

Contactor TECO CU-16

(110V Coil)

Thermal Overload

Relay TECO RHN-10K

(22–30A)

IMPORTANT: This magnetic switch toggles a motor ON and OFF, and helps provide thermal overload

protection for the motor if the operating temperature gradually increases due to heavy work loads. The

thermal overload relay inside is not designed to cut power in the event of a sudden motor overload or

stall. To help protect a motor from this type of overload, the power supply circuit must be properly

sized for the full-load current rating of the motor.

OPERATION: When pushed, the green ON button on the outside cover of the magnetic switch allows

current to flow to the magnetic coil, which pulls the contactor closed. The main current then passes

through the thermal overload relay to the motor. If the motor begins to overheat, the relay breaks the

magnetic field, which opens the contactor and cuts current to the motor. The red OFF button manually

breaks the magnetic field, which opens the contactor and disconnects the current to the motor.

Figure 1. Model D4137 magnetic

switch.

Electrocution or

fire could occur if

this switch is not

installed or adjust-

ed by a qualified

electrician!