Cnliua, 12 1 cnpw cnliu – Sharp FO-475TH User Manual

Page 70

Advertising
background image

UX-258TH
FO-475TH

8 – 2

2. Description

2-1. Relay board unit

1. Remove the TEL/LIU PWB, control PWB and Power Supply PWB

from this unit, and mount the relay board unit instead.

Before connecting the wiring to the relay board unit, set the test
PWB switches to the fixed position.

2. The setting is as follows.

The recording paper sensor (PSNS) is operated by OR of the mechani-
cal unit switch and the test PWB switch. When performing installation in
the machine unit, set the test PWB switches to the fixed position.

Mechanical unit

PWB to be tested

Actual operation with mechanical unit

Recording paper
sensor

ON/OFF operation

OFF (Photo interrupter
is interrupted.)

PWB sensor check

Recording paper
sensor

ON/OFF operation

OFF

POWER

SUPPLY

PWB

TEL/LIU

PWB

CHECK

CONTROL

PWB

DOOR

SENSOR

RELAY CABLE

DON'T SEPARATE

UNIT

TP3

(PSNS)

TP3

(PSNS)

TP1(DG)

TP2(+5V)

C

K

A

E

These cables are connected from the extension board
and the checked control PWB at TP1 thru TP3 (signals
of DG, +5V and PSNS).

EXTENSION PWB

NOTE

Relay
cable

CNLIUA

CHECK
CONTROL
PWB

TEL/LIU
PWB

12

1

CNPW

CNLIU

POWER
SUPPLY
PWB

The relay cables are used as one pair.

The sensor is wired as shown in the following figure.

The door swich and hook switch are manually operated.

Advertising