Star Micronics MP111MP-24G-A User Manual

Page 15

Advertising
background image

– 12 –

3.6

Timing Chart

(1) Printing Action

Fig. 3-7 Printing action

ON

MOTOR

PF MOTOR

OFF

HIGH

HP-sig

LOW

HIGH

T2-sig

LOW

HIGH

T1-sig

LOW

PRINT

T1-sig: Type 1660 Hz, Max. 1710 Hz (Software and CPU should be designed at Max. 2000 Hz.)
Printing speed: T1-sig 1600 Hz = Approximately 3.84 lines/sec. 1710 Hz = 3.96 lines/sec.
Paper feed action must be carried out within the carriage reversal area.

ON

T0

T2

Forward print area (322 pulses)

1/6 Inch = 24 Steps

Forward print area

After print
Motor OFF Timing

Backward print area
(322 pulses)

Carriage reversal

area
(110 pulses)

TYP. 66.3 ms
MIN. 64.3 ms

TYP. 66.3 ms
MIN. 64.3 ms

Carriage reversal

area
(110 pulses)

T4

T1

T-1

T3

T322 T323

T754

T-1

T755

T0 (T863)

T1

T433

T490