EN

Advanced Recording Operations

3-862-713-31(1)/CED/SP

DECK A / DECK B

PAUSE

P

ª / ·

PAUSE

P

ª / ·

§

P

R

r

§

P

R

r

p

ª

·

0

g

)

PAUSE

CLEAR

BACK

FRONT

REC MUTE

REC

PAUSE

REC MUTE

REC

ON FILTER

ON

OFF

(AMS)

(AMS)

0

)

(AMS)

(AMS)

p

ª

·

– RMS +

RMS/START

MEMORY

RESET

MEMORY

A

B

COUNTER

SET

CHECK

DISPLAY

DECK A

DECK B

A+B REC

HIGH/NORMAL

DOLBY NR

B

C

S

RMS

AUTO CAL(START

P

)

DUBBING A

B

START(DECK B

P

)

PITCH CONTROL

+

Ø

ON

ø

OFF

A

a

RELAY

DIRECTION MODE

AUTO

REC LEVEL

FADER

ARL

π

SYNCHRO

PHONES

0

1

2

3

4

5

6

7

8

9

10

RESET

Adjusting Bias and Recording
Level Calibration
Automatically

Since there are many different types of cassettes on the
market, your tape deck automatically sets the
appropriate equalization characteristics and bias
current for each tape type (ATS: Automatic Tape
Selection). However, you can get better recording
results by doing the automatic bias current and the
recording level calibration.

4

Press PAUSE

P to start the automatic calibration

procedure.
The automatic calibration procedure starts (i.e.,
recording test tones, rewinding, and playing
back).
During the calibration, the counter changes from
9 to 0.

Advanced Recording Operations

1

Insert the cassette you want to record on into
either deck.
Make sure the record-protect tabs on the cassette
have not been removed.

2

Press DECK A or DECK B until “CAL” appears in
the display.

3

Press

· or ª to select the side of the tape to be

recorded.

When the automatic calibration procedure ends,
the tape rewinds to the original position, the
counter returns to normal and the tape deck stops.

5

Start the actual recording (see page 6).

To cancel the automatic calibration function

Press

p on the deck you’re using.

If “A” or “B” flashes continuously

The automatic calibration procedure has been interrupted
by:
— The end of the tape. Reverse the tape direction or rewind

the tape to a new position that allows recording of the
test tone.

— Damaged tape or dirty heads. Change the cassette or

clean and demagnetize the heads (see page 19).

Updating the calibration setting

If you insert a cassette and “[A] CAL” or “CAL [B]”
appears in the display, it means that automatic
calibration data in that deck for that tape type (I, II or
IV) exists. However, we recommend that you repeat
the automatic calibration procedure each time you
insert a new cassette since cassettes of the same type
also vary in their characteristics.

Before recalibrating, be sure to turn off “[A] CAL” or
“CAL [B]” by pressing DECK A or DECK B. Then start
from Step 2 of the automatic calibration procedure.

Press

The front side

·

The reverse side

ª

To select

CA.

L9

CAL B

REC

6/11-17_TC-WE825S.31(1)EN