Indicators

Warning Message

Caution Message

Symptom

Cause and Remedy

The LAMP/COVER
indicator flashes in
orange. (Repetition rate
of 2 flashes)

• The lamp cover or the air filter cover is detached.

c Attach the cover securely (1 pages 49 and 51).

The LAMP/COVER
indicator flashes in
orange. (Repetition rate
of 3 flashes)

• The lamp has reached the end of its life.

c Replace the lamp (1 page 49).

• The lamp has reached a high temperature.

c Wait for 60 seconds until the lamp cools, then turn on the

power again.

:

/

1 switch flashes in

red. (Repetition rate of 2
flashes)

• The internal temperature is unusually high.

c Check to ensure that nothing is blocking the ventilation holes.

• The projector is being used at a high altitude.

c Ensure that “High Altitude Mode” in the INSTALL SETTING

menu is set to “On.”

:

/

1 switch flashes in

red. (Repetition rate of 4
flashes)

The fan is broken.

c Consult with qualified Sony personnel.

:

/

1 switch flashes in

red. (Repetition rate of 6
flashes)

Unplug the AC power cord from the wall outlet after the

:

/

1

switch stops flashing, plug the power cord to the wall outlet, then
turn the projector on again. If the

:

/

1

switch flashes in red and the

problem persists, the electrical system has failed.

c Consult with qualified Sony personnel.

Message Lists

Message

Meaning and Remedy

Please replace the Lamp
and clean the Filter.

• It is time to replace the lamp and clean the air filter.

c Replace the lamp (1 page 49) and clean the filter (1 page

51).

• When this message appears even after replacing the lamp, the

task has not been completed.
c Perform the operation of steps 10 to 13 on page 50.

Message

Meaning and Remedy

Not applicable!

You have pressed the wrong button.

c Press the appropriate button.