Siemens Simatic Industrial PC IPC427C User Manual

Page 139

Advertising
background image

Detailed descriptions

16.4 I/O Address Areas

SIMATIC IPC427C
Operating Instructions, 04/2009, A5E02414743-01

139

16.4.4

CAN base address register (write only, address 066h)

A 512 byte window is created in the I/O area for the CAN controller (Philips SJA1000). The

block itself only needs 32 or 128 bytes of this depending on the operating mode. The

address window can be selected in 1024 byte steps between 4000h and 7C00h through the

CAN base address register (write only, address 066h).
A limited selection can be preset in the BIOS Setup.

Note
The CAN base address register shares its I/O address with other registers. The watchdog

enable register / 066h select register therefore must be selected before access.

Meaning of the bits

CAN base address register (write only, address 066h, Address register selection 1)
Bit

Description

7 6 5 4 3 2 1 0

0 0 Reserved (Write: 00)

0 1

Reserved (Write:01)

0 0 0 0

40h

.

.

.

.

.

.

.

.

.

.

1 1 1 1

7Ch

Sets the high byte of the CAN base address

01nnnn00

Advertising