22

GB

Specifications

Amplifier section

POWER OUTPUT
Rated Power Output*

8 ohms 1 kHz, THD 0.7%:
110 W + 110 W
4 ohms 1 kHz, THD 0.7%:
120 W + 120 W

Power requirements 230 V AC, 50/60 Hz

* Measured under the following conditions:

Power requirements: 230 V AC, 50/60 Hz

(in countries/area in Europe
other than UK)
240 V AC, 50/60 Hz
(in UK and general area)

Frequency response

Inputs (Analog)

Output (Analog)

Inputs (Digital)

Output (Digital)

TONE

General

Power requirements 230 V AC, 50/60 Hz

(in countries/area in
Europe other than UK)
240 V AC, 50/60 Hz
(in UK and general area)

Power consumption 100 W
Power consumption (during standby mode)

0.5 W

AC outlets

1 switched, 100 W/0.4 A
MAX (in countries/area in
Europe other than UK)

Dimensions

430 Ч 173 Ч 428 mm
including projecting parts
and controls

Mass (Approx.)

14.0 kg

Supplied accessories

Operating Instructions (this manual)
Optimizer microphone ECM-AC1 (1)
AC power cord (mains lead) (1)
Remote commander RM-AAU010 (1)
R6 (size-AA) batteries (2)

Design and specifications are subject to
change without notice.

PHONO

RIAA equalization curve
± 0.5 dB

TUNER, SA-CD/CD,
TAPE

10 Hz – 40 kHz
± 3 dB (8 ohms)

PHONO

Sensitivity: 2.5 mV
Impedance: 50 kohms
S/N: 86 dB (A, 20 kHz
LPF)

TUNER, SA-CD/CD,
TAPE

Sensitivity: 150 mV
Impedance: 50 kohms
S/N: 96 dB (A, 20 kHz
LPF)

TAPE

Voltage: 150 mV
Impedance: 1 kohms

DIGITAL 1/2/3

Impedance: 75 ohms
S/N: 96 dB (A, 20 kHz
LPF)

DIGITAL 4

S/N: 96 dB
(A, 20 kHz LPF)

DIGITAL 4

S/N: 96 dB
(A, 20 kHz LPF)

TREBLE

±10 dB, 1 dB step

BASS

±10 dB, 1 dB step