0 power requirements – Sundance Spas 880 User Manual

Page 17

Advertising
background image

4.

Select the power supply cabinet inlet you want to use (Figure-A, Page 6),
Install the power cable through the large opening provided in the bottom
of the metal control box.

5.

Hot tubs with one main terminal block (Figure-B, Page 7) must be
supplied with 20 Amps. Note: the 850 series hot tub can be adapted to
use higher amperage circuits when available. Contact your Sundance
dealer for details.

6.

The electrical supply for this product must include a suitably rated
isolating switch and circuit breaker to comply with local electrical
regulations. This RCD/GFCI circuit breaker must be installed at the power
supply in the house electrical box.

7.

Connect wires to power terminal blocks TB1 and TB3 as illustrated
(Figure C, Page 7). TIGHTEN SECURELY! All wires must be hooked up
securely or damage could result.

8.

Install metal control box door and screws. Then reinstall the center wood
cabinet panel and screws.

6.0 Power Requirements

Sundance hot tubs are designed to provide optimum performance and
flexibility of use when connected to the maximum electrical service as listed
below. If you prefer, your Sundance dealer can perform a minor circuit board
modification to allow an alternate electrical service. The operational consider-
ations of these modifications are listed in the footnotes.

CAMEO, OPTIMA, MARIN and ALTAMAR Models
Voltage

230 VAC

230 VAC

Frequency

50Hz

50Hz

Max. Current Draw

16.6 Amps*

31.6 Amps**

Wattage:

3.8kW

7.3kW

Number of Wires

Three

Three

*

Standard 16.6 Amp (3.8kW) configuration: the heater will not operate
while both jets pumps are running.

** Alternate 31.6 Amp (7.3kW) configuration: the heater will operate

while both jet pumps are running.

Page 8

ENGLISH

Advertising
This manual is related to the following products:

850