Changing the microphone head – Sennheiser EW100 G2 User Manual

Page 21

Advertising
background image

21

Changing the microphone head

̈

First remove the batteries/accupack as described above and leave the
radiomicrophone open.

̈

Unscrew the sound inlet basket.

̈

Loosen the screw and put it to one side.

̈

Gently ease the capsule out of the contacts and then pull it out of the hou-
sing as shown. Do not touch the contacts and the diaphragm!

̈

Insert the new capsule.

̈

Secure the capsule by tightening the screw.

Note:

The screw mechanically secures the microphone capsule. If the screw is
missing, malfunctions may occur during tough use.

̈

Put on the sound inlet basket and identification ring supplied with the
new microphone head (NB: do NOT use the old basket, as the different
heads use slightly differing internal foam) and screw it tight.

̈

Insert the batteries/accupack.

̈

Close the radiomicrophone and put it into operation.

Note:

Microphone capsule, sound inlet basket and foam insert form an acoustic
unit and must therefore always be exchanged all together. Each micro-
phone head comes with a color-coded identification ring to distinguish
different microphone heads from each other (green = MD 835, blue = MD
845, red = ME 865).

Advertising