The serial plate is located in the rear right corner (see Figure 1 on page 3).

Replacement parts (including parts not listed in this manual) may be ordered either through a Southbend Authorized
Parts Distributor or a Southbend Authorized Service Agency.

When ordering parts, please supply the Model Number, Serial Number, Part Number, and Part Description.

T

ROUBLESHOOTING

Problem

Look for -

Not enough heat

– Low pressure in gas supply

– Restriction in gas piping and/or valves

– Misalignment of orifice to burner venturi
– Clogged burner orifice

– Incorrect burner orifice

Too much heat

– Incorrect orifices

– Malfunctioning or incorrectly set pressure regulator

Burner flame has excessive yellow tipping

– Obstruction of combustion-air intake on rear of broiler

– Exhaust gases blocked by objects sitting on top of broiler
– Low pressure in gas supply

– Misalignment of orifice to burner venturi

Burner flame fluttering

– Low gas pressure or obstruction in orifice

Burner flame lifting

– High gas pressure or air shutter on venturi out of adjustment

Slow burner ignition

– Pilot flame out of adjustment

Pilot outage

– Pilot flame out of adjustment

– Draft condition

– Pilot orifice clogged