1 identify device command, Identify device command – Seagate BARRACUDA XT ST33000651AS User Manual

Page 31

Advertising
background image

Barracuda XT SATA Product Manual, Rev. D

31

www.seagate.com

SATA Interface

4.3.1 Identify Device command

The Identify Device command (command code EC

H

) transfers information about the drive to the host following

power up. The data is organized as a single 512-byte block of data, whose contents are shown in on page

29.

All

reserved bits or words should be set to zero. Parameters listed with an “x” are drive-specific or vary with the state
of the drive.

The following commands contain drive-specific features that may not be included in the Serial ATA specification.

Write Log Extended

3F

H

Write Multiple

C5

H

Write Multiple Extended

39

H

Write Multiple FUA Extended

CE

H

Write Sectors

30

H

Write Sectors Without Retries

31

H

Write Sectors Extended

34

H

Write Uncorrectable

45

H

Word

Description

Value

0

Configuration information:
• Bit 15: 0 = ATA; 1 = ATAPI
• Bit 7: removable media
• Bit 6: removable controller
• Bit 0: reserved

0C5A

H

1

Number of logical cylinders

16,383

2

ATA-reserved

0000

H

3

Number of logical heads

16

4

Retired

0000

H

5

Retired

0000

H

6

Number of logical sectors per logical track: 63

003F

H

7–9

Retired

0000

H

10–19

Serial number: (20 ASCII characters, 0000

H

= none)

ASCII

20

Retired

0000

H

21

Retired

0400

H

22

Obsolete

0000

H

23–26

Firmware revision
(8 ASCII character string, padded with blanks to end of
string)

x.xx

27–46

Drive model number:
(40 ASCII characters, padded with blanks to end of string)

47

(Bits 7–0) Maximum sectors per interrupt on Read multiple
and Write multiple (16)

8010

H

Table 7 Supported ATA commands (continued)

Command name

Command code (in hex)

Advertising
This manual is related to the following products: