INSTALLATION INSTRUCTIONS

SK0-0055-001 HUMIDISTAT

The humidistat is designed for either return air duct or wall
mounting
. Packaged in a duct mount configuration, (For this type
mounting begin installation at the section labeled return air duct
installation on page 2.)
for conversion to a wall mount configuration
simply pull off the knob and remove the mounting screws and rotate the
control 180° and reattach the mounting base, (For this type mounting
begin installation at the section labeled wall mount installation on
page 3.)
.


DANGER

Do not cut or drill any air-conditioning or electrical
accessories during installation.

Fatal electrocution is possible if you contact a live wire.

Electrical power can cause electrical shock

Disconnect all electrical power supplied to the equipment
before beginning installation.

Blindness can occur if freon contacts your eyes.

CAUTION

Do not install on any electrical system over 30 VAC

CAUTION

All electrical wiring should comply with codes and
ordinances.

At Outside Temperatures

Recommended Setting

-20°F -30°C

15%

-10°F -25°C

20%

0°F -20°C

25%

+10°F -10°C

30%

+20°F -5°C

35%

Over 20°F Over 0°C

40%

Recommended Settings

Warning:
Adjusting the
humidity control
higher than the rec-
ommended setting
may cause conden-
sation resulting in
possible damage to
the

home.