Sentry Industries Sentry Xpress 4.0 User Manual

Sentry xpress, Digital temperature controller, Single-speed / ramp-hold version

Advertising
background image

The Sentry Xpress 4.0 micro processor is manufactured by the

Orton Ceramic Foundation and displays the CE mark.

Hr./Min.

When Lit

HIGHER

°C

°F

When Off
When Lit

START/

STOP

LOWER

Program

Review

Run

M I C R O P R O C E S S O R

TM

SENTRY

Xpress

4.0

Enter

Program

Skip Seg.

Add Hold

Change Temp.

T/C Offset

Alarm

Delay

Review

1

START/STOP Key

Starts and stops a firing.

Press after each

programming step. It works like the

Enter key on a computer.

Up Arrow Key

From

press

. Press

to select Single-Speed or

Ramp-Hold. Pages 6, 8

During a

Ramp-Hold firing, press the

.

will appear. Press

. The current segment ramp

or hold number will appear. To

skip, press

again. Page 8

During a

Ramp-Hold firing, press

repeatedly until

appears.

Press

. Each time you press

the

, the hold time for the

current segment will increase by 5

minutes. Then press

.

Page 8

During a Ramp-Hold firing,

press

repeatedly until

appears. Press

. Use

the arrow keys to change the target

temperature for the current seg-

ment. Then press

. Page 9

During a firing,

press

repeatedly until

appears. Press

. Use

the arrow keys to change the alarm

temperature. Press

. To si-

lence the alarm, press any key.

Page 9

At the

display, press

.

will appear. Use ar-

row keys to adjust the controller to

fire hotter or cooler. Press

to return to

. Page 12

Down Arrow Key

From

press

. The pro-

gram you have selected

will appear one step at a

time. When

ap-

pears, press

.

Page 4

From

press

.

Enter delay time. Press

twice. Page 4

During firing, press

. The program you

entered will appear one

step at a time. Page 4

Light is

on during pro-

gramming.

Light is

on during pro-

gram review.

Light

blinks during firing.

Temperature Display

Temperature

display is in °F.

Tem-

perature display is in °C.
See page 13 for instructions on

selecting °F or °C.

Time Display

: Sepa-

rates hours from minutes. Ex-

ample: Display shown above

is 1 hour and 30 minutes.

°F

°C

°C Display Dot

Sentry Xpress

Digital Temperature Controller

Single-Speed / Ramp-Hold Version

IM-221/2-06

Indicator

Lights

*These features are new with the Sentry Xpress 4.0. If your controller does

not have these features, it is an earlier controller.

Advertising