Warning indicators and messages, Self-diagnosis display/warning indicators – Sony GV-HD700E User Manual

Page 73

Advertising
background image

73

Tro
ubl
es
hoo

ting

Warning indicators and messages

If indicators appear on the LCD screen,
check the following.
You can fix some symptoms by yourself. If
the problem persists even after you have
tried a couple of times, contact your Sony
dealer or local authorized Sony service
facility.

C: (or E:) ss:ss (Self-diagnosis
display)

C:04:ss

• The battery pack is not an

“InfoLITHIUM” battery pack. Use an
“InfoLITHIUM” battery pack (p. 81).

• Connect the DC plug of the AC

Adaptor to the DC IN jack of your
VCR securely (p. 13).

C:06:ss

• The battery pack is too warm. Replace

the battery pack, or remove it and put it
in a cool place.

C:21:ss

• Moisture condensation has occurred.

Remove the cassette and leave your
VCR for at least 1 hour, then re-insert
the cassette (p. 84).

C:22:ss

• Clean the head using a cleaning

cassette (optional) (p. 85).

C:31:ss / C:32:ss

• Symptoms that are not described above

have occurred. Remove and insert the
cassette, then operate your VCR again.
Do not perform this procedure if
moisture condensation has occurred
(p. 84).

• Remove the power source. Reconnect it

and operate your VCR again.

• Change the cassette. Press the {RESET}

button (p. 90), and operate your VCR
again.

E:92:ss

• Turn on the power again to restore your

VCR by pressing {RESET} (p. 90).

101-1001(Warning indicator
pertaining to files)

• The file is damaged.
• The file is unreadable (p. 81).

E

(Battery level warning)

• The battery pack is nearly used up.
• Depending on the operating,

environment, or battery conditions, E
may flash, even if there are
approximately 5 to 10 minutes
remaining.

(Warning indicator

pertaining to battery pack
temperature)

• The battery pack is too hot. Replace the

battery pack, or remove it and put it in a
cool place.

(Warning indicator pertaining to

battery pack temperature)

• The battery pack is too cold. Replace

the battery pack, or remove it and put it
in a warm place.

%

(Moisture condensation warning)*

• Eject the cassette, remove the power

source, and then leave it for about 1
hour with the cassette compartment lid
open (p. 84).

Self-diagnosis display/Warning
indicators

Continued

,

Advertising
This manual is related to the following products: