7.2

Recommended Operating Conditions

PARAMETER

SYMBOL

MIN

MAX

UNITS

COMMENTS

Operating

Temperature

T

A

0

70

°C

1.8V supply voltage

V

DDA18PLL

V

DD18

1.71

1.98

V

3.3V supply voltage

V

DDA33

V

DDA33PLL

V

DD33CR

3.0

3.6

V

Voltage on any I/O pin

-0.3

5.5

V

If any 3.3V supply voltage drops
b e l o w 3 . 0 V, t h e n t h e M A X
becomes:

(3.3V supply voltage + 0.5)

Voltage on XTAL1

-0.3

V

DDA33

V

Voltage on XTAL2

-0.3

V

DD18

V

Table 7.1 DC Electrical Characteristics

PARAMETER

SYMBOL

MIN

TYP

MAX

UNITS

COMMENTS

I, IS Type Input Buffer

Low Input Level

High Input Level

Input Leakage

Hysteresis (‘IS’ Only)

V

ILI

V

IHI

I

IL

V

HYSI

2.0

-10

250

300

0.8

+10

350

V

V

uA

mV

TTL Levels

V

IN

= 0 to V

DD33

CR

Input Buffer with Pull-Up
(IPU)

Low Input Level

High Input Level

Low Input Leakage

High Input Leakage

V

ILI

V

IHI

I

ILL

I

IHL

2.0

+26

-10

0.8

+72

+10

V

V

uA

uA

TTL Levels

V

IN

= 0

V

IN

= V

DD33

CR

Input Buffer with Pull-Down
IPD

Low Input Level

High Input Level

Low Input Leakage

High Input Leakage

V

ILI

V

IHI

I

ILL

I

IHL

2.0

+10

-22

0.8

-10

-82

V

V

uA

uA

TTL Levels