Buffer Data

To buffer data, Code 39 buffering must be enabled, and a symbol must be read with a space
immediately following the start pattern.

t

Unless symbol overflows the transmission buffer, the unit gives a lo/hi beep to
indicate successful decode and buffering. See

Overfilling Transmission Buffer

.

t

Unit adds the message, excluding the leading space to the transmission buffer.

t

No transmission occurs.

Clear Transmission Buffer

To clear the transmission buffer, read a symbol which contains only a start character, a dash
(minus), and a stop character.

t

Unit issues a short hi/lo/hi beep to signal that the transmission buffer has been erased,
and no transmission has occurred.

t

Unit erases the transmission buffer.

t

No transmission occurs.